Service Manual
Features
l A energy
l Automatic controlling temperature
l Three-cooling system
l Bright VFD display
Haier Group
Serial number: ER03SM0415-01
Version number: 00.00
Edition: 2003-04-15
Models:
HRF- 329AA
HRF- 349AA
HRF- 369AA
HRF-369AA
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Service Manual

0 REFRIGERATOR Service Manual Features l A energy

Seite 2

9 System Flow Chart 1 Schematic diagram of System Flow Chart 2 Brief Description of System Flow Chart The refrigerating system of direct cooli

Seite 3

1 0Program Diagram Start T>Ts Read T Stop Read T T>Ts Ts+Td>t>Ts Ts+Td+2t>T>Ts+Td+t Ts+Td+2t>T>Ts+Td+t Ts+Td+mt>T>Ts+T

Seite 4 - Specifications

11 Maintenance Service and Trouble Shooting 1 No cooling Maintenance Service and Trouble Shooting Block by ic

Seite 5

12 2 The compressor doesn’t stop 1 The thermostatwas set at the coldest position.2 The ambient temperature is very high or the refrigerator is near b

Seite 6 - Safety precautions

13 3 Cooling capacity is insufficient YESRepair Does the refrigerant leak siowly?.NO Is the ambient temperature low than 16℃YESAdjust and instruct

Seite 7

14 4 The compressor doesn’t work Check the therostat is correct?Check the power source and power cord? Does the control panel has 220V power output?

Seite 8 - Parts and Functions

15 5 Normal Phenomena—Not Troubles for Refrigerators In a domestic refrigerator, there is not only a complicated electric control system, but also

Seite 9 - Function Schedule

16 6 Common Troubles in Refrigerators and Their Remedies Causes for troubles occurring in refrigerators are closely related to the quality of componen

Seite 10 - System Flow Chart

17Hums from a fully enclosed aggregate unit is the sound caused by overload indicating that the motor cannot be started normally ,meanwhile ,a clatte

Seite 11 - Program Diagram

18ambient temperature ,this means that most meshes of its screen has been clogged ,resulting in an obstructed flowing of refrigerant ,thus causing a d

Seite 12

1 CONTENT 1. Content………………………………………………………… 1 2. Product code illumination and Series Introduction…… 2 3. Specifications……………………….……..…………………. 3 4.

Seite 13 - Comprossor doesn't

19There are so many joints and sealed surfaces in a refrigerator ,accordingly ,quite a lot potential leak points do exist in the system .In troublesho

Seite 14 - Is the ambient

20 Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge capacity ,and hence the correspond

Seite 15

21 refrigerating effect is due to the accumulation of refrigerating oil left in the evaporator tubing in case no other troubles have been found . To c

Seite 16

22 heard ,and no will gush out of the process tube if you cut it open after shutdown . Remedy Check the whole machine , particularly those locations w

Seite 17

23 caused by dirt , tapping the suspicious clogged point (generally in the capillary or the connection joint of the filter) may cause the refrigerant

Seite 18

24 The cause of sudden stop of a compressor during its running is mostly that the gas suction pressure and/or discharge pressure exceed their respecti

Seite 19

25 temperature sensor has not been installed properly, frequent stoppage is also likely to occur. Remedy Try to adjust the temperature sensor’s positi

Seite 20

26 a) Check the input power circuit to see whether where is voltage of the power supply, namely, the circuit which is connected to the knife switch.

Seite 21

27 avometer. If short circuit occurs or the resistance of a certain phase is low, this means that short circuit does exist in the windings and/or betw

Seite 22

28 position is to be used for fast freezing or continuous running, its temperature for power off is too low, therefore, the compressor won’t stop and

Seite 23

2 Product code illumination and Series Introduction H R F — 369 AA Haier product Refrigerator Freezer Gross capacity (according to

Seite 24

29dissipation make the compressor running without stop. F. Electric leakage of refrigerator 1) Slight electric leakage Electric insulation has deterio

Seite 25

30 4) Inspection method To find the sources of noise ,press the vibration spot with your hand while the refrigerator is in operation and listen atten

Seite 27

3 Specifications Models HRF-329AA HRF-349AA HRF-369AA Net capacity (L) 239 259 289 Color Silver Silver Silver Power Supply (V/Hz) 220-240~/50 220-240

Seite 28

4 Safety precautions Safety precautions

Seite 29

5 Safety precautions

Seite 30

6 Safety precautions

Seite 31

7 Parts and Functions Parts and Functions

Seite 32

8 Function Schedule 1. Three cooling system There are three separate cooling parts in the refrigerator — refrigerator、freezer and soft freezer.sepe